DEUTZ Power Solutions Single-Phase Soundproofed Genset
Home » DEUTZ Engines » DEUTZ Power Solutions Gensets » DEUTZ Power Solutions Single-Phase Soundproofed Genset
DEUTZ single-phase soundproof diesel generators are used worldwide for a wide range of applications. Although they are not as powerful as our 3-phase generator models, the single-phase 50 HZ and 60 HZ power generators are lauded for their portability and use in domestic and commercial settings. A must-have tool on construction sites where sound levels may be an issue, DEUTZ soundless generators are an excellent alternative when access to mains power is limited.
Purchasing a single-phase generator may be all you need depending on your power requirements.
- General Details
- Technical Details
- Features and Benefits
Standard Configuration:
- DEUTZ G-Drive engine made in Germany
- Stamford brushless AVR electronic controlled generator
- Digital Controller DSE 4520 for standby application
- Battery charger
- Soundproof canopy
- Instrument panel
- Base-mounted fuel tank without retention basin
- Autonomy min 8 hs @ 75% PRP
- Silencer residential type, mounted
- Battery + isolator
- Rubber door blocking
- Operation manual
Options:
- Engine preheater kit
- Cold climate starting kit
- Automatic transfer switch (loose)
DPS SOUNDPROOFED GENSET - 220v 0.8 pf single phase outputs - 50HZ | |||
---|---|---|---|
Model | DPS | 25 SG | 35 SG |
Rated speed | rpm | 1500 | 1500 |
Rated voltage, | Voltage options | 220 | 220 |
Rated power (PRP) 1 Ph- reconnected | kVA | 20.2 | 28 |
Rated power (LTP) 1 Ph- reconnected | kVA | 21.3 | 30.7 |
Rated power (PRP) 1 Ph- reconnected | kW | 16.2 | 22.4 |
Rated power (LTP) 1 Ph- reconnected | kW | 17 | 24.6 |
Nominal current (LTP) 220 V phases | A | 89 | 130 |
Engine | |||
Make | DEUTZ | DEUTZ | |
Model | F3M2011 | F4M2011 | |
Rated COP/PRP mechanical power | kW | 22.1 | 29,0 |
Rated LTP mechanical power | kW | 24.5 | 35.2 |
Emissions | Cert | Tier 0-2 | Tier 0-2 |
Cooling system | Oil | Oil | |
Speed governing | Type | Mechanical | Mechanical |
Class | G2 | G2 | |
Number of cylinders | 3 | 4 | |
Engines configuration | IL | IL | |
Displacement | ltr | 2,3 | 3,1 |
Electrical equipment | V/dc | 12 | 12 |
Generator | |||
Generator | Make | Stamford | Stamford |
Generator | Model | S1L2-K | S1L2-Y |
Connection | Double Delta | Double Delta | |
Phases | Double Delta | 2PH+ N | 2PH + N |
Terminals | Number | 12 | 12 |
Winding | Config | 311 | 311 |
Protection | IP | 23 | 23 |
Electronic regulator | Model | AS540 | AS540 |
Precision | % | 10 | 10 |
Control Panel | |||
Control panel | Metal box | Mounted | Mounted |
Control module | Deepsea | 4520 MKII | 4520 MKII |
Automatic start | Deepsea | INC | INC |
On/off key | INC | INC | |
Emergency stop button | INC | INC | |
Auto transfer switch | OPT | OPT | |
Battery charger | INC | INC | |
Circuit breaker | INC | INC | |
Approx. Consumption | |||
Fuel (75% of load) | l/h | 4 | 5.7 |
Fuel (75% of load) | USG/h | 1.1 | 1.5 |
Fuel (75% of load) | g/Kwh | 218 | 217 |
Noise Level | |||
dbA at 7m | dbA | 69 | 69 |
Exhaust silencer | Internal | INC | INC |
DPS SOUNDPROOFED GENSET - 240v 0.8 pf single phase outputs - 60 HZ | ||||||
---|---|---|---|---|---|---|
Model | DPS | 25 SG | 35 SG | 50 SG | 65 SG | 90 SG |
Rated speed | rpm | 1800 | 1800 | 1800 | 1800 | 1800 |
Rated voltage, | Voltage options | 240 | 240 | 240 | 240 | 240 |
Rated power (PRP) 1 Ph- reconnected | kVA | 24 | 35.7 | 48 | 63 | 78.8 |
Rated power (LTP) 1 Ph- reconnected | kVA | 25.3 | 37.7 | 50 | 66 | 86.7 |
Rated power (PRP) 1 Ph- reconnected | kW | 19.2 | 28.6 | 38.4 | 50.4 | 60 |
Rated power (LTP) 1 Ph- reconnected | kW | 20.2 | 30.2 | 40 | 52.8 | 69.3 |
Nominal current (LTP) 240 V phases | A | 104 | 158 | 208 | 275 | 360 |
Engine | ||||||
Make | DEUTZ | DEUTZ | DEUTZ | DEUTZ | DEUTZ | |
Model | F3M2011 | F4M2011 | BF4M2011 | BF4M2011C | BF4M1013EC | |
Rated COP/PRP mechanical power | kW | 22.1 | 29,0 | 38,2 | 54,0 | 99 |
Rated LTP mechanical power | kW | 24.5 | 35.2 | 47.3 | 63.6 | 110 |
Emissions | Cert | Tier 0-2 | Tier 0-2 | Tier 0-2 | Tier 0 | Tier 0-2 |
Cooling system | Oil | Oil | Oil | Oil | Water | |
Speed governing | Type | Mechanical | Mechanical | Mechanical | Mechanical | Mechanical |
Class | G2 | G2 | G2 | G2 | G2 | |
Number of cylinders | 3 | 4 | 4 | 4 | 4 | |
Engines configuration | IL | IL | IL | IL | IL | |
Displacement | ltr | 2,3 | 3,1 | 3,1 | 3,1 | 4,8 |
Electrical equipment | V/dc | 12 | 12 | 12 | 12 | 12 |
Generator | ||||||
Generator | Make | Stamford | Stamford | Stamford | Stamford | Stamford |
Generator | Model | S1L2-K | S1L2-Y | UCI224F | UCI274C | UCI274D |
Connection | Double Delta | Double Delta | Double Delta | Double Delta | Double Delta | |
Phases | Double Delta | 2PH+ N | 2PH + N | 2PH + N | 2PH + N | 2PH + N |
Terminals | Number | 12 | 12 | 12 | 12 | 12 |
Winding | Config | 311 | 311 | 311 | 311 | 311 |
Protection | IP | 23 | 23 | 23 | 23 | 23 |
Electronic regulator | Model | AS540 | AS540 | AS540 | AS540 | AS540 |
Precision | % | 10 | 10 | 10 | 10 | 10 |
Control Panel | ||||||
Control panel | Metal box | Mounted | Mounted | Mounted | Mounted | Mounted |
Control module | Deepsea | 4520 MKII | 4520 MKII | 4520 MKII | 4520 MKII | 4520 MKII |
Automatic start | Deepsea | INC | INC | INC | INC | INC |
On/off key | INC | INC | INC | INC | INC | |
Emergency stop button | INC | INC | INC | INC | INC | |
Auto transfer switch | OPT | OPT | OPT | OPT | OPT | |
Battery charger | INC | INC | INC | INC | INC | |
Circuit breaker | INC | INC | INC | INC | INC | |
Approx. Consumption | ||||||
Fuel (75% of load) | l/h | 4 | 5.7 | 7.6 | 10.4 | 18.4 |
Fuel (75% of load) | USG/h | 1.1 | 1.5 | 2 | 2.8 | 4.9 |
Fuel (75% of load) | g/Kwh | 218 | 217 | 215 | 206 | 211 |
Noise Level | ||||||
dbA at 7m | dbA | 69 | 69 | 69 | 70 | 78 |
Exhaust silencer | Internal | INC | INC | INC | INC | INC |
Air-Intake Grids And Openings Suitable For Hot Climates
Specifically designed to operate in areas where the temperature is high, the DPS SG range is provided with side air-intake openings which grant proper air circulation. It also features rain protection and sound insulation.
Thanks to precise photometric testing, we detected the noisiest sections and applied high-efficiency, sound-absorbing panels.
Tough, Reliable, & Efficient DEUTZ Engine
Mechanical injection system with individual pump-line-injector system.
Operation with fuels with 500 ppm sulphur content is allowed without restrictions. Above this value it is possible with restrictions.
Durable design in main components. For long-term use and a long-lasting, attractive appearance, quality painting processes are essential. Enjoy the durability of a powder-coated paint on the base frame. Engine and generator painted according to the most stringent DEUTZ standards.
Fuel Savings & Low Operative Costs
Standard 500-hour maintenance interval up to 1000 hours.
Optimized for decreased fuel consumption and lower operating costs.
Fully Accessible
This series of gensets is engineered to run in harsh environments like deserts, farms and coastal regions while keeping parts of the machine accessible for easier maintenance. Cables and outlet door are equipped with condensation protection and cable feed through set up.
Integrated Fuel Tank
The fuel tank is placed inside the base frame. Every fuel tank is tested for leaks to ensure flawless operation. Optimal fuel tank capacity allows for less-frequent refueling in remote areas.
Control Panel
Control panel features:
- On/Off key
- Emergency stop button
- Control module DEEP SEA® 4520 MKII
- Primary brand circuit breakers
DEEP SEA® 4520 MKII
DSE4520 is a compact Auto Mains (Utility) Failure Control Module. Monitoring an extensive number of engine parameters, the module displays warning, shut-down and engine status information on the LCD screen.
Rating Definitions
Prime Rating (PRP)
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. Operating at a max mean load factor at 80% of nominal power. There is no limitation on the annual hours of operation, and this model can supply 10% overload power for one hour on a 12 hour period.
Standby Rating (LTP)
These ratings are applicable for supplying continuous electrical power(at variable load) in the event of utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Max operating hours 500 a year.
Standard Reference Conditions
Standard reference conditions include a 25°C(77°F) air inlet temp, 100m (328 ft) A.S.L. 30% humidity. Ratings in accordance with ISO 8528. Power factor cos φ 0.8. For de-rating factors depending on altitude and temperature please contact your DEUTZ® partner (for example TCD 2013 does not de-rate up to 40°C and 1500 m A.S.L).
Warranty
All equipment carries the DEUTZ standard manufacturer’s warranty.
For details on warranty coverage, please contact your responsible sales partner or visit our website: www.deutzamericas.com.
Brochure Download
Download BrochureContact Us
"*" indicates required fields